Over 1000 Total Lots Up For Auction at Two Locations - IL 11/19, NJ Cleansweep 11/21

With DBT, synthetic mammo could be a radiation-free alternative to digital mammo

por John R. Fischer, Senior Reporter | October 28, 2020
Women's Health
Combining digital breast tomosynthesis with synthetic mammography can still result in quality recall rates and cancer detection as when combining DBT and digital mammography
Radiologists can still get quality recall rates and cancer detection when combining digital breast tomosynthesis with synthetic mammography instead of digital mammography.

While DM is increasingly being used in combination with DBT in the U.S. rather than DM alone to conduct breast cancer screenings, early screenings that utilize synthetic mammography (SM) with DBT suggest it could be used as a non-radiation dose alternative to digital mammography, according to researchers at the University of Vermont and University of Pennsylvania.

“In synthetic imaging, the patient only receives the dose from the DBT portion of the exam,” authors Dr. Samantha Zuckerman, M.D., MBE, assistant professor of clinical radiology, division of breast imaging, and Dr. Emily Conant, M.D., professor of radiology and chief of the division of breast imaging at the University of Pennsylvania, told HCB News. “In combination DM/DBT imaging, the patient receives radiation dose from two examinations.”
stats
DOTmed text ad

Quality, speed, and peace of mind

GE HealthCare’s Repair Center Solutions are an ideal complement to your in-house service team. We service a broad range of mobile devices, including monitors and cardiology devices, parts, and portable ultrasound systems and probes.

stats
Creating a synthetic image requires a patient to undergo DBT. But instead of taking a single X-ray in one direction, multiple low dose X-rays are taken in an arc across the breast and are added together to create the image. A computer algorithm enhances areas of density in the “summed images”, such as calcifications, distortion, or ligaments.

To test this idea, the teams conducted a retrospective study that included 51,148 DM/DBT exams (between January 2012 and May 2016) and 31,929 SM/DBT exams (between June 2016 and March 2018) from the University of Vermont. The University of Pennsylvania contributed 34,106 DM/DBT cases (between October 2011, and October 2014) and 34,180 SM/DBT exams (between January 2015, and February 2018). Recall rate, biopsy rate, false-negative rate, cancer detection rate, positive predictive value, sensitivity, and specificity were calculated according to modality and institution, and descriptive statistics, χ2 tests, and logistic regression were also used in the analysis.

Unadjusted recall rate was 7% with SM/DBT compared to 7.9% with DM/DBT. Multivariable adjustment, however, showed SM/DBT had a slightly higher recall rate as well as slightly lower specificity compared with DM/DBT.

No statistical difference was found in biopsy rate, false-negative rate, cancer detection rate, invasive or in situ cancer detection rate, positive predictive value, or sensitivity for SM/DBT versus DM/DBT overall or within either institution.

“The main benefit of using synthetic mammography instead of digital mammography is an almost 50% decrease in radiation dose to the patient,” said Zuckerman and Conant.

The findings were published in Radiology.

You Must Be Logged In To Post A Comment