Over 1650 Total Lots Up For Auction at Two Locations - PA 07/14, NJ Cleansweep 07/16

stats
DOTmed text ad

Probo Medical | We Buy, Repair, and Sell New and Used Ultrasound Equipment

We provide sales, service, rental, and repair for ultrasound systems, probes, and C-arms. We have the largest inventory in the world. Contact us about our special offers on certified refurbished equipment! Call: 317-759-9210 Email: sales@probomedical.com.

stats
stats
DOTmed text ad

North America's Ultimate Probe Repair Lab & Certified Refurbished OEM Probes in Stock

North America's trusted source for ultrasound probe repair and certified refurbished OEM probes. Free evaluations, 1-year warranty, fast turnaround for GE, Philips, Sonosite, Canon, Toshiba, and more. Call (224) 265-7640 / Sales@Lenard.Healthcare

DOTmed Certified stats
Mako meter by RTI Group
Mako meter by RTI Group
New Product Showcase
spacer
Por página

Listas

Service For GE HEALTHCARE Repair GE Voluson E8 (BT12). Repair GE Voluson E8 (BT12).

Faulty Phenomenon A stripe appeared on the display of the RST board (PN: KTZ196358, KTZ280122). RST - impulse transmission board, 16 pieces are installed in the device (1 faulty). Sent the board... Veja mais

June 30  

Service For GE HEALTHCARE Repair GE Logiq E10 (version R3). Repair GE Logiq E10 (version R3).

Faulty Phenomenon GE Logiq E10: A malfunction was detected in the TX board, an element that controls the switching on/off of high voltage for supply to the acoustic module has failed. The device is... Veja mais

June 30  

Service For GE HEALTHCARE Repair device GE Philips Epiq 5. Repair device GE Philips Epiq 5.

Faulty Phenomenon Malfunction: error 607 indicates a malfunction in the data base solution: after restarting the PO device, it worked. Troubleshooting and Solutions Malfunction: error 607... Veja mais

June 30  

Service For GE HEALTHCARE GE Voluson E8 BT21 device repair. GE Voluson E8 BT21 device repair.

Faulty Phenomenon Malfunction: During the examination, echo-imaging disappears and everything turns into white color. Solution: repair RFM323 plate. Troubleshooting and Solutions Malfunction:... Veja mais

June 21  

Service For GE HEALTHCARE Repair device GE Voluson E10 B21. Repair device GE Voluson E10 B21.

Faulty Phenomenon Malfunction: during operation, a blue screen appears on the device. Sometimes the device does not turn on and the power button flashes yellow. Solution: repair the power supply... Veja mais

June 30  

Service For GE HEALTHCARE GE Voluson E8 BT13.5 device overhaul. GE Voluson E8 BT13.5 device overhaul.

Faulty Phenomenon Malfunction: during operation of the device, a break occurred and an error Error on Power management (error in the power supply block) appeared. Solution: repair the RFM and RSX... Veja mais

June 30  

Service For GE HEALTHCARE Repair GE Logiq E9. Repair GE Logiq E9.

Faulty Phenomenon Repair platform MRX192 (PN: 5393908) of Logiq E9 R6. Malfunction: the image quality has deteriorated, artifacts appeared on all transducers. Troubleshooting and Solutions Repair... Veja mais

June 30  

Service For GE HEALTHCARE Repair GE Logiq E9. Repair GE Logiq E9.

Faulty Phenomenon Repair platform MRX192 (PN: 5393908) of Logiq E9 R6. Malfunction: the image quality has deteriorated, artifacts appeared on all transducers. Troubleshooting and Solutions Repair... Veja mais

June 30  

Service For GE HEALTHCARE Repair GE Voluson S10 BT16. Repair GE Voluson S10 BT16.

Faulty Phenomenon Repair flat panel DBM128G Assy (PN: 5773602). Malfunction: during operation with the sensor on the display artifacts or interference of white color appear. Troubleshooting and... Veja mais

June 30  

Service For GE HEALTHCARE Repair GE Logiq E9 R6. Repair GE Logiq E9 R6.

Faulty Phenomenon Repair block of power supply Main Power Supply (PN: 5205054). Malfunction: absence of 48V for the computer power supply block and therefore the device does not turn on. ... Veja mais

June 30  

Service For GE HEALTHCARE Repair GE Vivid E95 (software 203). Repair GE Vivid E95 (software 203).

Faulty Phenomenon Repair the Main Power Supply (PN: GA200730-5) power supply block. Malfunction: when turning on the device, it shows the error "System Error". The logs indicated that the ultrasound... Veja mais

June 30  

Service For GE HEALTHCARE Repair GE Voluson E8 BT18. Repair GE Voluson E8 BT18.

Faulty Phenomenon Repair flatbed RFM323 (PN: RFM304073, RFM304141) (also used in versions BT17, BT19, BT20, BT21) malfunction: when turning on, the image begins to intensely display white noise... Veja mais

June 21  

Service For GE HEALTHCARE Repair GE Voluson E8 (versions BT08, BT09, BT10, BT12, BT13). (versions BT08, BT09, BT10, BT12, BT13).

Faulty Phenomenon Repair flat RSR14, RSR19 (PN: KTZ196357, KTZ196310) and RST15, RST20 (PN: KTZ196358, KTZ280122) malfunction: when turning on, the image begins to intensively display white noise... Veja mais

June 21  

Service For GE HEALTHCARE Repair GE Logiq E9 (version R3). Repair GE Logiq E9 (version R3).

Faulty Phenomenon Repair the Main Power Supply (PN: 5205052-7) power supply block. This power supply unit is also suitable for Vivid E9. Malfunction: does not turn on the device, no 48 V on the... Veja mais

June 21  

Service For GE HEALTHCARE Repair Voluson E10 BT21. Repair Voluson E10 BT21.

Faulty Phenomenon Repair of electronic volume transducer GE eM6C malfunction: error code (ASIC thermal info error 0x10A6), began to issue an error due to overheating, the cause of which is the... Veja mais

June 21