We provide sales, service, rental, and repair for ultrasound systems, probes, and C-arms. We have the largest inventory in the world. Contact us about our special offers on certified refurbished equipment! Call: 317-759-9210 Email: sales@probomedical.com.
North America's trusted source for ultrasound probe repair and certified refurbished OEM probes. Free evaluations, 1-year warranty, fast turnaround for GE, Philips, Sonosite, Canon, Toshiba, and more. Call (224) 265-7640 / Sales@Lenard.Healthcare
Faulty Phenomenon When using the 4C probe for abdominal scanning, the VE9 system occasionally displayed a vertical brightness boundary line on the image. The issue appeared intermittently and only... Veja mais
Faulty Phenomenon The 17-inch main monitor showed discoloration and streaks, while the workstation display remained normal - indicating a display-specific issue. Troubleshooting and Solutions GE... Veja mais
Faulty Phenomenon The GE Vivid E9 ultrasound system failed to start properly. During boot-up, the progress bar showed an error message, then the screen turned black and the system shut down... Veja mais
Faulty Phenomenon GE Vivid 7 ultrasound system showed poor color image quality with high-frequency abdominal probes, while the cardiac probe (M3S) worked normally with clear color images ... Veja mais
Faulty Phenomenon The GE Vivid 7 ultrasound system failed to start up. After pressing the On/Standby button, the system showed no response and could not begin normal operation. Troubleshooting... Veja mais
Faulty Phenomenon GE Voluson730 ultrasound system showed partial image loss across all connected probes, affecting imaging quality Troubleshooting and Solutions GE Voluson730 Ultrasound System... Veja mais
Faulty Phenomenon The system's operate keyboard remained locked even after pressing the unlock button, preventing normal operation. Troubleshooting and Solutions GE LOGIQ E9 Keyboard Lock... Veja mais
Faulty Phenomenon The GE Voluson E8 ultrasound system could start up and switch probes normally, but the scanning area showed no image, making examinations impossible. Troubleshooting and... Veja mais
Faulty Phenomenon The GE LOGIQ E9 ultrasound system frequently crashes during startup, preventing normal operation. Troubleshooting and Solutions GE LOGIQ E9 Frequent Crashes - Power Supply... Veja mais
Faulty Phenomenon The portable ultrasound unit shuts down automatically during startup, only reaching about halfway through the boot process. Troubleshooting and Solutions GE LOGIQ E Portable... Veja mais
Faulty Phenomenon The Vivid E9 system repeatedly shut down unexpectedly during normal operation. It could be restarted, but the issue recurred after some time. Troubleshooting and Solutions GE... Veja mais
Faulty Phenomenon The system repeatedly experienced blue screen errors with "system file missing" messages. While reinstalling the system provided a temporary fix, the problem returned within a... Veja mais
Faulty Phenomenon The main monitor showed a blurry display while the system booted normally. The touchscreen display and all system functions worked properly. Troubleshooting and Solutions GE... Veja mais
Faulty Phenomenon GE Vivid 7 system worked normally for about 30 minutes after startup, then suddenly went blank and became completely unresponsive to restart attempts. Troubleshooting and... Veja mais
Faulty Phenomenon GE Vivid 7 system experienced repeated crashes over three weeks: - Initially crashed twice within two weeks - Completely failed to start in third week - Displayed error:... Veja mais