Used SCOTTCARE ViaCare ECP Unit SE de Vende - DOTmed Lista #2935047:
This Item is no longer available.

Click here to see the 1 Equipment Listings matching 'SCOTTCARE ViaCare ECP Unit' on DOTmed

Post a free Request For Proposal for a SCOTTCARE ViaCare ECP Unit and get quotes from our Gold Service Dealers
SCOTTCARE ViaCare ECP Unit for sale SCOTTCARE ViaCare ECP Unit for sale SCOTTCARE ViaCare ECP Unit for sale
SCOTTCARE ViaCare ECP Unit for sale SCOTTCARE ViaCare ECP Unit for sale SCOTTCARE ViaCare ECP Unit for sale

Vende Se SCOTTCARE ViaCare ECP Unit

  • Condition : Used - Excellent
  • Weight : 525.00 Lbs
  • Quantity : 1
  • In Stock : Yes
  • Date : October 30, 2019

Item Description

Seller assumes all responsibility for this listing.

Listing: #2935047

  • Condition: Used - Excellent
  • Brand: SCOTTCARE
  • Type: ECP Unit
  • Model: ViaCare
  • MPN: ViaCare
  • Amperage: 20
  • Depth: 82 inches
  • Frequency (Hz): 60
  • Height: 29 inches
  • Power Supply Voltage: 220
  • Warranty: 30 days limited
  • Width: 34 inches
  • Year of Manufacture: 2009
ScottCare ViaCare ECP system in like new condition. ViaCare was introduced in 2012 based off of original Nicore/ACS ECP System and offers the latest and most advanced patient safety and comfort design features available sold.

Treatment Duration Timer
• 10-60 minutes; 5 minute increments
• Treatment and air/vacuum pump stop when set time expires
Treatment Cuffs
• Durable & cleanable, high denier Nylon with Velcro closure
• 3 sizes to fit all patient types
• Buttock and thigh cuffs are separate for better fit
Table
• Motorized, continuously adjustable backrest – 0 to 45 degrees continuous
• Safe Working Load: t 350 lbs. /160 kg
• Easy to clean, fluid resistant fabric
• Quick connect hoses attach without tools
System Protection
• Bed Base ON/OFF switch is fused
• Air/Vacuum Pump relay is overload protected
• Air/Vacuum Pump is thermally protected
Patient Protection
• Automatic vacuum deflation of cuffs on early/extra systole
• Over pressure limit protection
• Treatment is suspended during episodes of high or low heart rate
• Emergency stop button
• Auditory alarms: heart rate out of limits, oxygen saturation out of limits, lack of adequate
triggering signal, loss of communication between computer and ECP device
• Air to cuffs is actively cooled
Power Requirements
• 1 – 110 VAC 60Hz 15 A standard or hospital grade outlet
• 1 – 220 VAC 60Hz 20 A dedicated, twist and lock outlet
• 220VAC 50Hz compatibility upon request
Operating Environment
• Temperature 65-75ºF/18-24º C
• Air conditioning capacity: at least 8800 BTU per hour
• Relative Humidity 35-6%
• Absence of electromagnetic interference in the area (e.g.: MRI device)
• Free of flammable anesthetics






Seller Information
  • Location :USA
Shop with confidence