Over 1650 Total Lots Up For Auction at Four Locations - NJ 04/25, MA 04/30, NJ Cleansweep 05/02, NJ 05/08

spacer
Listing 4714697 Listing 4714697 Listing 4714697 Listing 4714697 Listing 4714697 Listing 4714697 Listing 4714697 Listing 4714697 Listing 4714697 Listing 4714697
Listing 4714697 Listing 4714697 Listing 4714697 Listing 4714697 Listing 4714697 Listing 4714697 Listing 4714697 Listing 4714697 Listing 4714697 Listing 4714697

For Sale SCHILLER SP-1 Pulmonary Function Tester with SP150 Flow Sensor Respiratory Analyzer

  • Original Price :$1,065.33 USD
  • Asking Price :$799.00 USD (25% Off) [convert]
  • Condition : Used - Good
  • Est. Shipping(US) : $30.00 USD
  • Qty. Available : 1
  • In Stock : Yes
  • Ships Within : 2 Days
  • Date : April 19, 2024
  • Listing # : 4714697
  • credit-card
  • credit-card
  • credit-card
  • credit-card
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #4714697

  • Condition: Used - Good
  • Brand: SCHILLER
  • Type: Respiratory Analyzer
  • Model: SP-1 Pulmonary Function Tester with SP150 Flow Sensor
  • MPN: SP1
  • Power Supply Voltage: 115 VAC
  • S/N: 540. 12301
  • Year of Manufacture: 2013
  • Warranty: 7 day inspection
This 2014 Spirovit SP-1 with its original flow meter, a calibrator and consumables was retired when the rural clinic it was used in closed due to long term staffing issues. It was well maintained and comes with good batteries and no known issues. It is due for its annual biomedical inspection. The buyer has a choice of a Schiller 3 liter calibration syringe or one branded Welch Allyn both of which have been used with this instrument . Two other unassigned similar 3 L syringes are also available as are 70 SP150 disposable plastic sensor tubes (P/N 2.100077). If you just need an SP1, without anything else, we also have one of those available.

According to the Swiss manufacturer of this instrument:
The SPIROVIT SP-1 is a unique solution to simplify complex lung function testing. The high-resolution patient incentive screen displays real-time flow/volume loops and detailed measurement matrices. The data can be either printed within seconds or transmitted to a PC.

Disposable Sensor SP-150
With SCHILLER’s unique SP-150 disposable sensors, the risk of cross-contamination is reduced to a minimum. The small, lightweight sensors are low-cost and completely disposable. Simply remove, discard and replace the sensor after each patient performance. No need for disinfection, easy handling and saving time: these are maximum benefits for both patient and physician!

Reusable Sensor SP-20
SCHILLER’s SP-20 reusable sensors are small, lightweight and very easy to clean. The low-cost filters provide the most economical method of performing pulmonary function tests.

Features
• FVC, SVC, MVV, MV and pre/post medication tests with choice of predicted normals.
• Simple operation
• Internal memory for up to 100 tests (optional)
• Built-in mains and battery operation
• Ready-to-file reports within seconds on 3.5” (90 mm) paper
• Comparison of predicted and actual values
• Automatic interpretation
• Data transmission via built-in RS-232 interface to PC-based data management program SEMA for long term storage, retrieval and trends
• Everything in one box … memory, battery, printer, patient incentive screen
• Affordable, fast, reliable, labelled

Specifications:
* 290 x 210 x 69 mm, approximately 2.9 kg; // 11.4 x 8.3 x 2.7 in, app. 6.3 pounds
* Power Supply Requirements: 100–115V, nominal 115V, 50/60 Hz;
* Independent operation with built-in rechargble battery and charger unit, LED indication for line or battery operation
* Battery Charging Time: 15 hours for a completely discharged battery (Battery Charging < 3 hours to 60 % capacity)
* Battery Capacity: 6 hours of normal use
* Power Consumption: max. 28VA
* Storage: Memory for up to 100 tests
* Liquid Crystal Display
– Liquid crystal display for graphic and alphanumeric representation
– Resolution: 192 x 64 dots
– Contrast is manually variable via keyboard
Chart Paper: Thermo-reactive, Z-folded, width 90 mm/3.6in, perforation each page
Printing Process: High-resolution thermal printhead, 8 dots/mm
Paper Speed: 25 mm/s
Safety Standards: MDD 93/42/EEC, Annex II; EN 60601-1: 1990; IEC 60601-1-2
Safety Class: BF according to IEC 60601-1
Protection Class:
– I according to IEC 60601-1, CSA 22.2 and UL 2601 (units with internal battery)
– Ila according to MDD 93/42/EEC (medical guideline)
Conformity: -0123 according 93/42/EEC
Control Panel and Keyboard: User-friendly rubber keys, LED indicators
Environmental Conditions:
– Temperature, operating: 10° to 40° C/50° to 104° F
– Temperature, storage: -10° to 50° C/14° to 122° F
– Relative Humidity: 25 to 95 % (not condensed)
– Pressure, operating: 700–1060 hPa
Standard Interfaces: 1x RS-232 serial interface
SPIROVIT SP-1 Basic Unit: Performs four inspiratory and expiratory pulmonary function tests with choice of predicted normals
Accessories included:
– 1 pneumotach sensor (choice of SP-150 disposable)
– 1 power cable
– 10 x pack of paper

Software Options (not included) :
– SEMA PC software for validation and archiving of test data on PC
– Memory for up to 100 tests
Measured Values:
FVC: FVC, FEV0.5, FEV1.0, FEV3.0, FEV0.5/FVC, FEV1.0/FVC, FEV3.0/FVC, FEF0.2–1.2,
FEF25–75%, FEF75–85%, PEF, MEF75%, MEF50%, MEF25%, FIVC, FIV1.0, FIV1.0/FIVC,
FIV1.0/FVC, PIF, MIF50%
SVC: SVC, ERV, IRV, TV
MV: MV, RR, TV
MVV: MVV, RR, TV
Prediction Equation:
– Adults: ECCS, Crapo, Morris, Knudson, Knudson 76, Austria, Berglund, Finnish, Indian, Composite, Polgar
– Children: Quanier & Tammeling, Austria, India, Knudson, Knudson 76, Polgar
– Comparison pre/post medication possible
– Extrapolated predicted values
Presentation:
– Flow/volume loop
– Flow/time plot
– Measurement values table
Standards Compliance: ATS 94, OSHA, NIOSH

SPIROVIT SP-150 Pneumotach Flow Sensor for Pulmonary Function Testing with Disposable Sensors:
Dimensions: 118 x 36 x 28 mm, app. 120 g; // 4.6 x 1.4 x 1.1 in., app. 0.26 pounds
Measuring Method: Pneumotachometer
Measuring Ranges:
– Flow: 0 to ±16 l/s
– Volume: 0 to ±15 l
Measuring Accuracy: According ATS 1994
Flow Impedance: <0.2 mbar *s/l at 12 l/

70 x SP150 disposable plastic sensors are available separately on DOTmed. They are not included with this instrument as they would disproportionately increase the value of the package and as a result increase shipping costs. Not all buyers will want disposable sensors.

US customers pay only what is paid on checkout. No US or Canadian taxes or border related fees like tariffs will be applied to this item on purchase or when it is delivered.

This item is not for sale within Canada. Please contact the seller if clarification or an exception is required.

Overseas shipping will be at cost with Payment by wire transfer or PayPal

*************************************************
DISCLAIMER:

Regardless of the origin of the equipment, documentation provided or identification appearing upon the equipment, the equipment described and offered here is in no way certified for, recommended for, or offered for any specific use. The buyer is purchasing an item(s) which may have been used for medical purposes and may have the potential to again be used for this purpose, however, unless otherwise specified, at the time of sale the item is not considered to be bio-medically certified for use in any jurisdiction. The purchased item(s) is simply a device which operates in the limited manner described in the listing and/or electronic and mechanical components.

The purchaser agrees that the seller shall not be held responsible or liable:

* for any injuries or damages, whether incidental or consequential, associated in any way with the equipment;

* for compliance with regulations on ownership or use of the purchased item within the jurisdiction in which the purchaser resides and/or uses the item.

The purchaser, by buying this equipment, indicates their acknowledgement of, and agreement to the terms of this disclaimer.

The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and other national/provincial/territorial/state and local regulatory agencies. If so, do not buy this item unless you are an authorized purchaser. If the item is subject to FDA regulation and it is to be used for regulated medical services in the USA, your payment for it indicates you are an authorized purchaser and will comply with these regulations. If you have questions about legal obligations regarding sales of medical devices, you should consult with the FDA or the regulatory authorities in the jurisdiction in which the item is to be used

Return Policy

7 Day Return Policy. Customer must pay the return shipping costs when returning a product. If you find the item is not as described in the ad it may be returned for a purchase price refund. Generally, all of our items have an inspection warranty which kicks in upon delivery for a period of 7 to 14 days. It is not an operational warranty as most items sold on DOTmed require biomedical certification before use. If you require additional coverage please contact us prior to purchase.
Seller Information
Raynor Shine Ent
Shop with confidence
Citi Capital Groupspacer
Send the Seller a message: